Emerson 1F86U-42WF Manuals & User Guides. User Manuals, Guides and Specifications for your Emerson 1F86U-42WF Thermostat. Database contains 1 Emerson 1F86U-42WF Manuals (available for free online viewing or downloading in PDF): Installation manual. Appliance manuals and free pdf instructions. Find the user manual you need for your home appliance products and more at ManualsOnline. Easy-to-see Changeover: Manual. Emerson 1F86-0244 Blue 2 Thermostat, Single Stage, Non-ProgrammableHas the manual and works fine. Bottom right in pic. Do NOT contact me. User manuals from the category White Rodgers Thermostat 105, White Rodgers EMERSON BLUE 1F98EZ-1421 user manual White Rodgers EMERSON 109, White Rodgers BLUE 2'. Nov 14, 2010 I had a basic Emerson thermostat (White Rodgers 1f86-0244) installed a few months back and cooling functions worked fine. But now that I'm trying to use the heat function in Fan AUTO mode it does not work. The fan never activates even when the set point is above current temp. Mar 25, 2009 Find helpful customer reviews and review ratings for 1F86-244 THERMOSTAT at Amazon.com. Read honest and unbiased product reviews from our users.
Advertising
7
TROUBLESHOOTING
Reset Operation
If a voltage spike or static discharge blanks out the display
or causes erratic thermostat operation, you may need to
reset the thermostat. To reset, the System Switch must be
in Cool or Heat. Simultaneously press
and
buttons
for approximately 10 seconds until the display goes blank. If
the thermostat has power, has been reset and still does not
function correctly contact your heating/cooling service person
or place of purchase.
Symptom
Possible Cause
Corrective Action
No Heat/No Cool/No Fan
common problems)
1. Blown fuse or tripped circuit breaker.
2. Furnace power switch to OFF.
3. Furnace blower compartment door or
panel loose or not properly installed.
Replace fuse or reset breaker.
Turn switch to ON.
Replace door panel in proper position to engage safety
interlock or door switch.
No Heat
1. System Switch not set to Heat.
2. Loos connection to thermostat or
system
3. Heating System requires service or
thermostat requires replacement.
Set System Switch to Heat and raise setpoint above
room temperature.
Verify thermostat and system wires are securely at-
tached.
Diagnostic: Set System Switch to Heat and raise the set-
point above room temperature. Within a five minutes the
thermostat should make a soft slick sound. This sound
usually indicates the thermostat is operating properly.
If the thermostat does not click, try the reset operation
listed above. If the thermostat does not click after being
reset contact your heating and cooling service person or
place of purchase for a replacement. If the thermostat
clicks, contact the furnace manufacturer or a service per-
son to verify the heating system is operating correctly.
No Cool
1. System Switch not set to Cool.
2. Loose connection to thermostat or
system.
3. Cooling System requires service or
thermostat requires replacement
Set System Switch to Cool and lower setpoint below
room temperature.
Verify thermostat and system wires are securely at-
tached.
Same procedures as diagnostic for No Heat condition
except set the thermostat to Cool and lower the setpoint
Emerson Thermostat 1f86 0244
below the room temperature. There may be up to a five
minute delay before the thermostat clicks in Cooling if the
compressor lock-out option is selected in the configura- Roxio creator nxt pro 6 user manual.
tion menu (Item 5).
Heat, Cool or Fan Runs
Constantly
Constantly
1. Possible short in wiring.
2. Possible short in thermostat.
3. Possible short in Heat/Cool/Fan
system.
4. Fan Switch set to Fan On.
Check each wire connection to verify they are not shorted
or touching together. No bare wire should stick out from
under terminal screws. Try resetting the thermostat as
described below. If the condition persists, the manufac-
turer of your system or service person can instruct you on
how to test the Heat/Cool/ system for correct operation. If
the system operates correctly, replace the thermostat.
Furnace Cycles Too Fast
or Too Slow Cooling
Cycles Too Fast or Too
Slow (narrow or wide
temperature swing)
or Too Slow Cooling
Cycles Too Fast or Too
Slow (narrow or wide
temperature swing)
1. The location of the thermostat and/or
the size of the Heating or Cooling
System may be influencing the cycle
rate.
Item 3 (CR Heat) or 4 (CR Cool) in the Configuration
Menu is the adjustment that controls the cycle rate. If an
acceptable cycle rate is not achieved using the FA (Fast)
or SL (Slow) adjustment contact a local service person
for additional suggestions.
Thermostat Setting and
Thermometer Disagree
Thermometer Disagree
1. Thermostat thermometer setting
requires adjustment.
Emerson 1f86-0244 Thermostat User Manual Rth230b
The thermometer can be adjusted +/- degrees as listed in
item 7 of the Configuration Menu. No other adjustment is
possible.
Blank Display and/or
Keypad Not Responding
Keypad Not Responding
1. Voltage Spike or Static Discharge.
If a voltage spike or static discharge occurs use the Re-
set Operation listed above.